The nosuid
mount option can be used to prevent
execution of setuid programs in /var/tmp
. The SUID and SGID permissions
should not be required in these world-writable directories.
Add the nosuid
option to the fourth column of
/etc/fstab
for the line which controls mounting of
/var/tmp
.
The presence of SUID and SGID executables should be tightly controlled. Users should not be able to execute SUID or SGID binaries from temporary storage partitions.
The following script can be run on the host to remediate the issue.
#!/bin/bash
# Remediation is applicable only in certain platforms
if ( [ ! -f /.dockerenv ] && [ ! -f /run/.containerenv ] && findmnt --kernel "/var/tmp" > /dev/null || findmnt --fstab "/var/tmp" > /dev/null ); then
function perform_remediation {
# the mount point /var/tmp has to be defined in /etc/fstab
# before this remediation can be executed. In case it is not defined, the
# remediation aborts and no changes regarding the mount point are done.
mount_point_match_regexp="$(printf "^[[:space:]]*[^#].*[[:space:]]%s[[:space:]]" "/var/tmp")"
grep "$mount_point_match_regexp" -q /etc/fstab \
|| { echo "The mount point '/var/tmp' is not even in /etc/fstab, so we can't set up mount options" >&2;
echo "Not remediating, because there is no record of /var/tmp in /etc/fstab" >&2; return 1; }
mount_point_match_regexp="$(printf "^[[:space:]]*[^#].*[[:space:]]%s[[:space:]]" /var/tmp)"
# If the mount point is not in /etc/fstab, get previous mount options from /etc/mtab
if ! grep -q "$mount_point_match_regexp" /etc/fstab; then
# runtime opts without some automatic kernel/userspace-added defaults
previous_mount_opts=$(grep "$mount_point_match_regexp" /etc/mtab | head -1 | awk '{print $4}' \
| sed -E "s/(rw|defaults|seclabel|nosuid)(,|$)//g;s/,$//")
[ "$previous_mount_opts" ] && previous_mount_opts+=","
# In iso9660 filesystems mtab could describe a "blocksize" value, this should be reflected in
# fstab as "block". The next variable is to satisfy shellcheck SC2050.
fs_type=""
if [ "$fs_type" == "iso9660" ] ; then
previous_mount_opts=$(sed 's/blocksize=/block=/' <<< "$previous_mount_opts")
fi
echo " /var/tmp defaults,${previous_mount_opts}nosuid 0 0" >> /etc/fstab
# If the mount_opt option is not already in the mount point's /etc/fstab entry, add it
elif ! grep "$mount_point_match_regexp" /etc/fstab | grep -q "nosuid"; then
previous_mount_opts=$(grep "$mount_point_match_regexp" /etc/fstab | awk '{print $4}')
sed -i "s|\(${mount_point_match_regexp}.*${previous_mount_opts}\)|\1,nosuid|" /etc/fstab
fi
if mkdir -p "/var/tmp"; then
if mountpoint -q "/var/tmp"; then
mount -o remount --target "/var/tmp"
fi
fi
}
perform_remediation
else
>&2 echo 'Remediation is not applicable, nothing was done'
fi
The following playbook can be run with Ansible to remediate the issue.
- name: 'Add nosuid Option to /var/tmp: Check information associated to mountpoint'
command: findmnt --fstab '/var/tmp'
register: device_name
failed_when: device_name.rc > 1
changed_when: false
when: ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman",
"container"] and "/var/tmp" in ansible_mounts | map(attribute="mount") | list
)
tags:
- configure_strategy
- high_disruption
- low_complexity
- medium_severity
- mount_option_var_tmp_nosuid
- no_reboot_needed
- name: 'Add nosuid Option to /var/tmp: Create mount_info dictionary variable'
set_fact:
mount_info: '{{ mount_info|default({})|combine({item.0: item.1}) }}'
with_together:
- '{{ device_name.stdout_lines[0].split() | list | lower }}'
- '{{ device_name.stdout_lines[1].split() | list }}'
when:
- ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
and "/var/tmp" in ansible_mounts | map(attribute="mount") | list )
- device_name.stdout is defined and device_name.stdout_lines is defined
- (device_name.stdout | length > 0)
tags:
- configure_strategy
- high_disruption
- low_complexity
- medium_severity
- mount_option_var_tmp_nosuid
- no_reboot_needed
- name: 'Add nosuid Option to /var/tmp: If /var/tmp not mounted, craft mount_info
manually'
set_fact:
mount_info: '{{ mount_info|default({})|combine({item.0: item.1}) }}'
with_together:
- - target
- source
- fstype
- options
- - /var/tmp
- ''
- ''
- defaults
when:
- ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
and "/var/tmp" in ansible_mounts | map(attribute="mount") | list )
- ("--fstab" | length == 0)
- device_name.stdout is defined and device_name.stdout_lines is defined
- (device_name.stdout | length == 0)
tags:
- configure_strategy
- high_disruption
- low_complexity
- medium_severity
- mount_option_var_tmp_nosuid
- no_reboot_needed
- name: 'Add nosuid Option to /var/tmp: Make sure nosuid option is part of the to
/var/tmp options'
set_fact:
mount_info: '{{ mount_info | combine( {''options'':''''~mount_info.options~'',nosuid''
}) }}'
when:
- ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
and "/var/tmp" in ansible_mounts | map(attribute="mount") | list )
- mount_info is defined and "nosuid" not in mount_info.options
tags:
- configure_strategy
- high_disruption
- low_complexity
- medium_severity
- mount_option_var_tmp_nosuid
- no_reboot_needed
- name: 'Add nosuid Option to /var/tmp: Ensure /var/tmp is mounted with nosuid option'
mount:
path: /var/tmp
src: '{{ mount_info.source }}'
opts: '{{ mount_info.options }}'
state: mounted
fstype: '{{ mount_info.fstype }}'
when:
- ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
and "/var/tmp" in ansible_mounts | map(attribute="mount") | list )
- mount_info is defined
- (device_name.stdout is defined and (device_name.stdout | length > 0)) or ("--fstab"
| length == 0)
tags:
- configure_strategy
- high_disruption
- low_complexity
- medium_severity
- mount_option_var_tmp_nosuid
- no_reboot_needed