Add nosuid Option to /var

このページは日本語には対応しておりません。随時翻訳に取り組んでいます。翻訳に関してご質問やご意見ございましたら、お気軽にご連絡ください。

Description

The nosuid mount option can be used to prevent execution of setuid programs in /var. The SUID and SGID permissions should not be required for this directory. Add the nosuid option to the fourth column of /etc/fstab for the line which controls mounting of /var.

Rationale

The presence of SUID and SGID executables should be tightly controlled.

Remediation

Shell script

The following script can be run on the host to remediate the issue.

#!/bin/bash

# Remediation is applicable only in certain platforms
if ( [ ! -f /.dockerenv ] && [ ! -f /run/.containerenv ] && findmnt --kernel "/var" > /dev/null || findmnt --fstab "/var" > /dev/null ); then

function perform_remediation {
    
        # the mount point /var has to be defined in /etc/fstab
        # before this remediation can be executed. In case it is not defined, the
        # remediation aborts and no changes regarding the mount point are done.
        mount_point_match_regexp="$(printf "^[[:space:]]*[^#].*[[:space:]]%s[[:space:]]" "/var")"

    grep "$mount_point_match_regexp" -q /etc/fstab \
        || { echo "The mount point '/var' is not even in /etc/fstab, so we can't set up mount options" >&2;
                echo "Not remediating, because there is no record of /var in /etc/fstab" >&2; return 1; }
    


    mount_point_match_regexp="$(printf "^[[:space:]]*[^#].*[[:space:]]%s[[:space:]]" /var)"

    # If the mount point is not in /etc/fstab, get previous mount options from /etc/mtab
    if ! grep -q "$mount_point_match_regexp" /etc/fstab; then
        # runtime opts without some automatic kernel/userspace-added defaults
        previous_mount_opts=$(grep "$mount_point_match_regexp" /etc/mtab | head -1 |  awk '{print $4}' \
                    | sed -E "s/(rw|defaults|seclabel|nosuid)(,|$)//g;s/,$//")
        [ "$previous_mount_opts" ] && previous_mount_opts+=","
        # In iso9660 filesystems mtab could describe a "blocksize" value, this should be reflected in
        # fstab as "block".  The next variable is to satisfy shellcheck SC2050.
        fs_type=""
        if [  "$fs_type" == "iso9660" ] ; then
            previous_mount_opts=$(sed 's/blocksize=/block=/' <<< "$previous_mount_opts")
        fi
        echo " /var  defaults,${previous_mount_opts}nosuid 0 0" >> /etc/fstab
    # If the mount_opt option is not already in the mount point's /etc/fstab entry, add it
    elif ! grep "$mount_point_match_regexp" /etc/fstab | grep -q "nosuid"; then
        previous_mount_opts=$(grep "$mount_point_match_regexp" /etc/fstab | awk '{print $4}')
        sed -i "s|\(${mount_point_match_regexp}.*${previous_mount_opts}\)|\1,nosuid|" /etc/fstab
    fi


    if mkdir -p "/var"; then
        if mountpoint -q "/var"; then
            mount -o remount --target "/var"
        fi
    fi
}

perform_remediation

else
    >&2 echo 'Remediation is not applicable, nothing was done'
fi

Ansible playbook

The following playbook can be run with Ansible to remediate the issue.

- name: 'Add nosuid Option to /var: Check information associated to mountpoint'
  command: findmnt --fstab '/var'
  register: device_name
  failed_when: device_name.rc > 1
  changed_when: false
  when: ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman",
    "container"] and "/var" in ansible_mounts | map(attribute="mount") | list )
  tags:
  - configure_strategy
  - high_disruption
  - low_complexity
  - medium_severity
  - mount_option_var_nosuid
  - no_reboot_needed

- name: 'Add nosuid Option to /var: Create mount_info dictionary variable'
  set_fact:
    mount_info: '{{ mount_info|default({})|combine({item.0: item.1}) }}'
  with_together:
  - '{{ device_name.stdout_lines[0].split() | list | lower }}'
  - '{{ device_name.stdout_lines[1].split() | list }}'
  when:
  - ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
    and "/var" in ansible_mounts | map(attribute="mount") | list )
  - device_name.stdout is defined and device_name.stdout_lines is defined
  - (device_name.stdout | length > 0)
  tags:
  - configure_strategy
  - high_disruption
  - low_complexity
  - medium_severity
  - mount_option_var_nosuid
  - no_reboot_needed

- name: 'Add nosuid Option to /var: If /var not mounted, craft mount_info manually'
  set_fact:
    mount_info: '{{ mount_info|default({})|combine({item.0: item.1}) }}'
  with_together:
  - - target
    - source
    - fstype
    - options
  - - /var
    - ''
    - ''
    - defaults
  when:
  - ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
    and "/var" in ansible_mounts | map(attribute="mount") | list )
  - ("--fstab" | length == 0)
  - device_name.stdout is defined and device_name.stdout_lines is defined
  - (device_name.stdout | length == 0)
  tags:
  - configure_strategy
  - high_disruption
  - low_complexity
  - medium_severity
  - mount_option_var_nosuid
  - no_reboot_needed

- name: 'Add nosuid Option to /var: Make sure nosuid option is part of the to /var
    options'
  set_fact:
    mount_info: '{{ mount_info | combine( {''options'':''''~mount_info.options~'',nosuid''
      }) }}'
  when:
  - ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
    and "/var" in ansible_mounts | map(attribute="mount") | list )
  - mount_info is defined and "nosuid" not in mount_info.options
  tags:
  - configure_strategy
  - high_disruption
  - low_complexity
  - medium_severity
  - mount_option_var_nosuid
  - no_reboot_needed

- name: 'Add nosuid Option to /var: Ensure /var is mounted with nosuid option'
  mount:
    path: /var
    src: '{{ mount_info.source }}'
    opts: '{{ mount_info.options }}'
    state: mounted
    fstype: '{{ mount_info.fstype }}'
  when:
  - ( ansible_virtualization_type not in ["docker", "lxc", "openvz", "podman", "container"]
    and "/var" in ansible_mounts | map(attribute="mount") | list )
  - mount_info is defined
  - (device_name.stdout is defined and (device_name.stdout | length > 0)) or ("--fstab"
    | length == 0)
  tags:
  - configure_strategy
  - high_disruption
  - low_complexity
  - medium_severity
  - mount_option_var_nosuid
  - no_reboot_needed